IAI America CON-PG User Manual

Page 36

Advertising
background image

30

5. Operation of CON Controllers

SCON-CA
IO monitor screen

Touching [MoniMain] switches to the main monitor
display
Touching [Data Mon] changes the display to show
data such as the current position and control voltage.
Touching [LC Mon] changes the display to show data
such as the current position and force feedback.
Touching [Axis No.] switches the screen to one
where you can select an axis.

x Input

The status of each input port is shown. ON is lit. OFF is unlit.

x Output

The status of each output port is shown. ON is lit. OFF is unlit.

SCON-CA
Data monitor screen

Touching [MoniMain] switches to the main monitor
display
Touching [IOMoni] changes the display to one
showing only I/Os.
Touching [LC Mon] changes the display to show data
such as the current position and force feedback.
Touching [Axis No.] switches the screen to one
where you can select an axis.

x Position

The current position is shown.

x Velocity

The speed is shown.

x Pulse count

The pulse count is shown. Touching [Pulse Count] displays the pulse count.
(The pulse count is shown in the pulse-train control mode.)

x Current Rate

The command value of electrical current is shown as a percentage of the rated
current.

x Current

The command value of electrical current is shown. Touch [Current] to display the
command value.

x Alarm Code

The applicable alarm code is shown.

x Servo

The servo ON status is shown. ON is lit. OFF is unlit.

x Home

The home return status is shown. Lit, if home return has completed.

x Control Voltage

The voltage of the control power supply is shown.

x Motor Voltage

The voltage of the motor power supply is shown.

x PCB Temperature

The PCB temperature is shown.

Touch [Current] to display [Current Rate].
Touch [Current Rate] to display [Current]

x Position

The current position is shown.

x Velocity

The speed is shown.

x Pulse count

The pulse count is shown. Touching [Pulse Count] displays the pulse count. (The pulse
count is shown in the pulse-train control mode.)

x Current Rate

The command value of electrical current is shown as a percentage of the rated current.

x Current

The command value of electrical current is shown. Touch [Current Rate] to display the
command value.

x AlarmCode

The applicable alarm code is shown.

x Servo

The servo ON status is shown. ON is lit. OFF is unlit.

x Home

The home return status is shown. Lit, if home return has completed.

x MotorVoltage

The voltage of the motor power supply is shown.

x PCB Temperature The PCB temperature is shown.

Advertising