IAI America CON-PG User Manual

Page 178

Advertising
background image

172

7. Operation of MEC Controllers

[7]

Ecology ...

When Ecology is enabled, you can have the motor power (servo) turned off
automatically upon elapse of a specified period to save power after completion
of positioning. Set the applicable period beforehand using a parameter.

Parameter No.

Parameter name

Initial

value

Setting

range

10

Auto servo OFF delay time [sec]

1

0 ~ 9999

[Pushing toward the end point or intermediate point]

[Pushing = pulling toward the start point or intermediate point]

Approach

Push

com

pl

ete

(A po

sition

comple

te

signal

i

s

ou

tpu

t)

Speed

Push band

Start point

Start position

of push

Time

End point

(intermediate point)

Return

Push

com

pl

ete

(A po

sition

comple

te

signal

i

s

ou

tpu

t)

Speed

Time

Push band

Start point

End position of

push

Start point

(intermediate point)

Advertising
This manual is related to the following products: