<3. Parameter Setting>

3-16

IM 01C25R02-01E

3.2.6 Differential Pressure Signal Low Cut

Mode Setup

Low cut mode can be used to stabilize the

differential pressure output signal near the zero

point. The Low cut is applied to the differential

pressure used to flow calculation. The low cut point

can be set from 0 to 20% of output. (Hysteresis for

the cut point: ±10% of the cut point )
Follow the procedure below to change the Low cut

mode and Low cut point.

• Procedure to call up the display

DD (HART 5/7)

DTM (HART 7)

[Root Menu] → Basic setup →

Others →

DTM (HART 5) Configuration → Analog Output →
→ Low cut

Set from 0 to 20% of output

→ Low cut

mode

Select “On” or “Off”

(%)

50

(%)

50

0

50

(%)

50

(%)

DP

Output

DP

Output

For low cut in Off mode

Input

20

20

0

For low cut in On mode

Input

F0302.ai

Figure 3.1

Low Cut Mode

The low cut point has hysteresis so that the output

around the point is behaved as below figure.

<Example>

Low cut mode: On

Low cut: 20.00%

F0303.ai

Setting range: 0 to 20%

2%

2%

4mA

DP Output

Low cut point

Input

Hysteresis

fixed at 10%

of the cut point

7.2mA(20%)

3.2.7 Impulse Line Connection Orientation

Setup

This function reverses the impulse line orientation.

This function is used when the high pressure side

impulse line and the low pressure side impulse line

are connected reverse by mistake.
Follow the procedure below to assign the high

pressure impulse line to the L side of the transmitter.

• Procedure to call up the display

DD (HART 5/7)

DTM (HART 7)

[Root Menu] → Basic setup →

Others →

DTM (HART 5) Configuration → Pressure Sensor →
→ H/L Swap

Select “Normal” or “Reverse”