<5. Parameter Summary>

5-2

IM 01C25R02-01E

Function

Label

Item

Contents

Default value Handling

*

1

Device

information

Country

HART 7

Country code

US, JP, DE, FR, ES, RU, CN JP

W

Dev id

Device ID

R

Distributor

Yokogawa

R

Drain vent matl

Drain and vent plug material

W

Extra No.

Customizaion number

R

Ext SW

External zeroing permission

Disabled or Enabled

Enabled

W

Fill fluid

Fill fluid

W

Final asmbly num

Final assembly number

W

Fld dev rev

Field device revision

R

Gasket matl

Gasket material

W

Isoltr matl

Capsule material

W

Mftr Date

Manufactured date

R

Model 1/MS Code 1 Memo field for MS code 1

32 alphanumerics

W

Model 2/MS Code 2 Memo field for MS code 2

32 alphanumerics

W

Model 3/MS Code 3 Memo field for MS code 3

32 alphanumerics

W

Num of RS

Number of remote seal

W

Process Conn matl Process connection material

W

Process Conn size Process connection size

W

Process Conn type Process connection type

W

PT100 Serial No.

Serial number of PT100

W

RS fill fluid

Fill fluid of remote seal

W

RS Isoltr matl

Remote seal material

W

RS type

Remote seal type

W

Serial No.

Serial number

R

Sofftware rev

Software revision

R

Style No.

Style number

Style number of product

R

Universal rev

Universal revision

16 alphanumerics

R

Cfg chng count

HART 7

Configuration change counter

0

R

Reset Cfg chng flag

HART 7

Reset Configuration change flag

M

Device Profile

HART 7

Device Profile

Process

automation

device

R

Max dev vars

HART 7

Max device variables

3

R

Model

Model

Model name + Measurement

span in the Suffix Codes

Ex) “EJX910 M”

R

Device

Variable

Simulation

Simulate

HART 7

Execution of device variable

simulation

Execute the simulation

M

Diag

Applicable

Diag Applicable

Appicable blockage detection

Disabled or Enabled

RG

Diag DPComp Diag DPComp

fDP compensation selection

Compensation or

Non-compensation

Compensation

WG

Diag Error

Diag Error

Results detected by ILBD or Heat

trace monitoring

RG

*1: Handling: R-Read only, W-Read & Write, M-Method, G-Applicable for option code DG6