Yokogawa EJX930A User Manual

Page 91

Advertising
background image

<5. Parameter Summary>

5-9

IM 01C25R02-01E

Function

Label

Item

Contents

Default value Handling

*

1

Process

variables

QV is

HART 7

Current QV

R

QV Data Quality*

3

HART 7

Device variable process data

quality

Device variable process data

quality of QV

R

QV Limit Status

HART 7

Device variable limit status

Device variable limit status

of QV

R

% Range

HART 7

% of range value (PV value in %)

-2.50 to 110.00%

R

% Range Data

Quality*

3

HART 7

Device variable process data

quality

Device variable process data

quality of % Range

R

% Range Limit

Status

HART 7

Device variable limit status

Device variable limit status of

% Range

R

SP

Static pressure value

R

SP Data Quality*

3

HART 7

Device variable process data

quality

Device variable process data

quality of static pressure

R

SP Limit Status

HART 7

Device variable limit status

Device variable limit status of

static pressure

R

SP Update time

period

HART 7

SP Update time period

100ms

R

Change SV Assgn

Change the allocation to SV

M

SV

SV value

Unit specified in SV Unit

R

SV is

Current SV

R

SV Data Quality*

3

HART 7

Device variable process data

quality

Device variable process data

quality of SV

R

SV Limit Status

HART 7

Device variable limit status

Device variable limit status

of SV

R

Total Flow

Total flow value

R

Total Flow Data

Quality*

3

HART 7

Device variable process data

quality

Device variable process data

quality of total flow

R

Total Flow Limit

Status

HART 7

Device variable limit status

Device variable limit status of

total flow

R

Total Flow Update

time period

HART 7

Total Flow Update time period

1s

R

Change TV Assgn

Change the allocation to TV

M

TV

TV value

R

TV is

Current TV

R

TV Data Quality*

3

HART 7

Device variable process data

quality

Device variable process data

quality of TV

R

TV Limit Status

HART 7

Device variable limit status

Device variable limit status

of TV

R

*1: Handling: R-Read only, W-Read & Write, M-Method, G-Applicable for option code DG6

*2: Max three Burst Messages (Burst Message 1, Burst Message 2, Burst Message 3)

Advertising
This manual is related to the following products: