APPENdIX 1. LIST OF PArAMETErS FOr EACH BLOCK OF rOTAMASS

a-7

IM 01R04B05-00E-E 3rd edition July 30, 2010 -00

all Rights Reserved. Copyright © 2005, Rota Yokogawa

TA0102-4.EPS

1)

Initial value: All limits are set to plus or minus infinity (+INF or -INF), which is the same as no limit. IEEE 754-1985 defines the

floating point representation of plus and minus infinity.

AUTO

Rel.

Index

Index

Parameter Name

Factory
Default

Write

Mode

Explanation

AUTO

AUTO

AUTO

AUTO

17

18

19

20
21

22

23

24

25
26

27

28
29

30
31

32

0.0 (AI5)
0.0 (AI6)

0

0

AUTO

LOW_CUT

PV_FTIME

0

HI_HI_LIM

FIELD_VAL

UPDATE_EVT

BLOCK_ALM

ALARM_SUM

ACK_OPTION

ALARM_HYS

HI_HI_PRI

HI_PRI
HI_LIM

LO_PRI

LO_LIM

LO_LO_PRI

1. #INF

1)

AUTO

0xffff

0.5%

33

LO_LO_LIM

HI_HI_ALM

AUTO

AI5 AI6

Raw value of the field device in percent of thePV range,
with a status reflecting the Transducer condition, before
signal characterization (L_TYPE), filtering (PV_FTIME), or
low cut (LOW_CUT).

The block alarm is used for all configuration, hardware,
connection failure or system problems in the block. The
cause of the alert is entered in the subcode field. The first
alert to become active will set the Active status in the
Status attribute. As soon as the Unreported status is
cleared by the alert reporting task, another block alert may
be reported without clearing the Active status, if the
subcode has changed.

The current alert status, unacknowledged states,
unreported states, and disabled states of the alarms
associated with the function block.

Selection of whether alarms associated with the block will
be automatically acknowledged.
Amount the PV must return within the alarm limits before
the alarm condition clears. Alarm Hysteresis is expressed
as a percent of the PV span. 0 to 50

Priority of the high high alarm. 0, 1, 3 to 15

Priority of the high alarm. 0, 1, 3 to 15
The setting for high alarm in engineering units.

Priority of the low alarm. 0, 1, 3 to 15
The setting for the low alarm in engineering units.
Priority of the low low alarm. 0, 1, 3 to 15
The setting of the low low alarm in engineering units

.

The status for high high alarm and its associated time stamp

.

The status for high alarm and its associated time stamp

.

The status of the low alarm and its associated time stamp

.

The status of the low low alarm and its associated time
stamp.

This alert is generated by any change to the static data

.

Sets low cut point of output. This low cut value become
available by setting "Low cutoff" to "IO-OPTS".

Time constant of a single exponential filter for the PV, in
seconds.

The setting for high high alarm in engineering units.

AUTO

0

AUTO
AUTO

34

HI_ALM

35

LO_ALM

36

LO_LO_ALM

1. #INF

1)

-1. #INF

1)

0
-1. #INF

1)

AUTO

4417

4418

4419

4420

4421

4422

4423

4424

4425
4426

4427
4428
4429
4430

4431

4432

4433

4434
4435
4436

4517

4518

4519

4520

4521

4522

4523

4524

4525
4526

4527
4528
4529
4530

4531

4532

4533

4534
4535
4536

Advertising