9. EXPLOSION PrOTECTEd TyPE INSTrUMENTS

9-13

IM 01R04B05-00E-E 3rd edition July 30, 2010 -00

all Rights Reserved. Copyright © 2005, Rota Yokogawa

9.2.4 Ex-relevant marking on name plate

rCCT3 option /FF3:

Control Drawing no. 8300026

Class I, Division 1; Group a, B, C, D

Class II / III, Division 1, Group E, F, G

aEx d [ia] IIC, Class I, Zone 1, t6

Conduit Seals required within 18 inches.

use Conductors rated 70°C

tYPE nEMa 4X, IP67

WARNING

WaIt 15 MIn. aFtER PoWER-DISConnECtIon

BEFoRE oPEnInG tHE EnCLoSuRE.

rCCF31 option /FF3:

Control Drawing no. 8300027

Class I, Division 1; Group a, B, C,D

aIS Class I / II / III, Division 1, Group a, B, C, D, E, F, G

Class II / III, Division 1, Group E, F, G

aEx d [ia] IIC, Class I, Zone 1, t6

Conduit Seals required within 18 inches.

use Conductors rated 70°C

tYPE nEMa 4X, IP67

WARNING

WaIt 15 MIn. aFtER PoWER-DISConnECtIon

BEFoRE oPEnInG tHE EnCLoSuRE.

rCCT3 option /FF3 /dS:

Control Drawing no. 8300026

Class I, Division 1; Group a, B, C, D

Class II / III, Division 1, Group E, F, G

aEx d [ia] IIC, Class I, Zone 1, t6

Conduit Seals required within 18 inches.

use Conductors rated 70°C

tYPE nEMa 4X, IP67

WARNING

WaIt 15 MIn. aFtER PoWER-DISConnECtIon

BEFoRE oPEnInG tHE EnCLoSuRE.

Dual Seal

rCCS3 option /FS1:

Control Drawing no. 8300027

IS Class I, Division 1; Group a, B, C, D, t6

Class II / III, Division 1, Group E, F, G

aEx ia IIC, Class I, Zone 0

use Conductors rated 20°C above max. ambient

temperature

tYPE nEMa 4X, IP67
temperature Class see Control Drawing

rCCT3 option /FF3 /HP:

Control Drawing no. 8300026

Class I, Division 1; Group C, D

Class II / III, Division 1, Group E, F, G

aEx d [ia] IIB, Class I, Zone 1, t6

Conduit Seals required within 18 inches.

use Conductors rated 70°C

tYPE nEMa 4X, IP67

WARNING

WaIt 15 MIn. aFtER PoWER-DISConnECtIon

BEFoRE oPEnInG tHE EnCLoSuRE.

rCCF31 option /FF3 /HP:

Control Drawing no. 8300027

Class I, Division 1; Group C, D

aIS Class I / II / III, Division 1, Group C, D, E, F, G

Class II / III, Division 1, Group E, F, G

aEx d [ia] IIB, Class I, Zone 1, t6

Conduit Seals required within 18 inches.

use Conductors rated 70°C

tYPE nEMa 4X, IP67

WARNING

WaIt 15 MIn. aFtER PoWER-DISConnECtIon

BEFoRE oPEnInG tHE EnCLoSuRE.

rCCT3 option /FF3 /HP /dS:

Control Drawing no. 8300026

Class I, Division 1; Group C, D

Class II / III, Division 1, Group E, F, G

aEx d [ia] IIB, Class I, Zone 1, t6

Conduit Seals required within 18 inches.

use Conductors rated 70°C

tYPE nEMa 4X, IP67

WARNING

WaIt 15 MIn. aFtER PoWER-DISConnECtIon

BEFoRE oPEnInG tHE EnCLoSuRE.

Dual Seal

rCCS3 option /FS1 /dS:

Control Drawing no. 8300027

IS Class I, Division 1; Group a, B, C, D, t6

Class II / III, Division 1, Group E, F, G

aEx ia IIC, Class I, Zone 0

use Conductors rated 20°C above max. ambient

temperature

tYPE nEMa 4X, IP67

temperature Class see Control Drawing

Dual Seal