(14) dlmeScheduledescriptor
this parameter exists for the same number as
the total number of domains, and each describes
the LaS schedule downloaded to the correspond-
ing domain. For the domain to which a schedule
has not yet been downloaded, the values in this
parameter are all zeros.

Element

Description

Sub-

index

Size

[bytes]

2


4


2

Indicates the version number of
the LaS schedule downloaded
to the corresponding domain.

Indicates the macro cycle of the
LaS schedule downloaded to
the corresponding domain.

Indicates the time resolution
that is required to execute the
LaS schedule downloaded to
the corresponding domain.

Version

Macrocycle
Duration

timeResolution

1


2


3

ta0614.EPS

(15) domain
Read/write: impossible; get-oD: possible

Carrying out the GenericDomainDownload com-
mand from a host writes an LaS schedule to the
domain.

A7.6 FAQs

Q1. When the LAS stops, a rOTAMASS does

not back it up by becoming the LAS.
Why?

a1-1. Is that RotaMaSS running as an LM?

Check that the value of BootoperatFunc-
tionalClass (index 367) is 2 (indicating that
it is an LM).

a1-2. Check the values of V(St) and V(tn) in all

LMs on the segment and confirm that the
following condition is met:

RotaMaSS

other LMs

V(St)  V(tn) <

V(St)  V(tn)

Q2. How can I make a rOTAMASS become

the LAS?

a2-1. Check that the version numbers of the ac-

tive schedules in the current LaS and the
RotaMaSS are the same by reading:

LinkScheduleListChar-

acteristicsRecord

(index 374 for a RotaMaSS)

- activeScheduleVersion (subindex 3)

a2-2. Make the RotaMaSS declare itself as and

become the LaS by writing:

• 0x00 (false) to PrimaryLinkMaster-

FlagVariable in the current LaS; and

• 0xFF (true) to PrimaryLinkMasterFlagVari-

able (index 364) in the RotaMaSS.

Q3. On a segment where a rOTAMASS

works as the LAS, another device cannot
be connected. Why?

a3-1. Check the following bus parameters that in-

dicate the bus parameter as being the LaS
for the RotaMaSS and the capabilities of
being the LaS for the device that cannot be
connected:

• V(St), V(MID), and V(MRD) of

RotaMaSS: ConfiguredLinkSettingsRe-
cord (index 369)

• V(St), V(MID), and V(MRD) of problem-

atic device: DlmeBasicInfo

then, confirm that the following conditions
are met:

RotaMaSS

Problematic Device

V(St)

>

V(St)

V(MID)

>

V(MID)

V(MRD)

>

V(MRD)

a3-2. Check that the node address of the prob-

lematic device does not lie within either
0x00 to 0x10 or the range of unused
(unpolled) node addresses determined by
the RotaMaSS LM parameter settings,
which is 0x00 to 0x10 or V(Fun) to V(Fun)
+ V(nuM). (Refer to Section 5.2, “network
Definition.”)

Q4. The LCd keeps showing “— — —”. It is

presumed that an LAS does not exist on
the bus or the rOTAMASS cannot estab-
lish communication with the LAS. What
should be done?

a4-1. Check that an LaS is connected on the

bus. (When using the RotaMaSS as the
LaS [which requires an option], perform
steps (1) to (3) in Section a6-3.)

a4-2. Make the parameters in the current LaS

match the capabilities parameter in the