TB120: HIST_Ord

Kind

Hex

Name

description

none

0x0000

no error

Error

0x0101

E-01

Frequency Fault

0x0102

E-02

Signal Fault

0x0103

E-03

EEPRoM Fault

0x0104

E-04

CPu Fault

0x0105

E-05

DSP Fault

0x0106

E-06

Sensor 1 Signal Fault

0x0107

E-07

Sensor 2 Signal Fault

0x0108

E-08

temp Sensor Fault

alarm

0x020E

a-14

Slug Detection

0x020F

a-15

Empty Pipe Detection

0x0210

a-16

Corrosion Detection

Warning

0x0301

W-01

Density Lower 0.3 kg/l

0x0302

W-02

Fixed Dens selected (Density only)

0x0303

W-03

Fixed temp selected

0x0304

W-04

Fixed Mass flow selected (MF only)

0x0306

W-06

autozero Value out of Range

0x0307

W-07

autozero Fluctuation out of Range

TB121: HIST_ABS_Err and TB117: Err_STATUS

Kind

Hex

Name

description

Error

0x00000001

E-01

Frequency Fault

0x00000002

E-02

Signal Fault

0x00000004

E-03

EEPRoM Fault

0x00000008

E-04

CPu Fault

0x00000010

E-05

DSP Fault

0x00000020

E-06

Sensor 1 Signal Fault

0x00000040

E-07

Sensor 2 Signal Fault

0x00000080

E-08

temp Sensor Fault

TB122: HIST_ABS_ALM and TB118: ALM_STATUS

Kind

Hex

Name

description

alarm

0x00002000

a-14

Slug Detection

0x00004000

a-15

Empty Pipe Detection

0x00008000

a-16

Corrosion Detection

TB123: HIST_ABS_WArNG and TB119: WArNG_STATUS

Kind

Hex

Name

description

Warning

0x00000001

W-01

Density Lower 0.3 kg/l

0x00000002

W-02

Fixed Dens selected (Density only)

0x00000004

W-03

Fixed temp selected

0x00000008

W-04

Fixed Mass flow selected (MF only)

0x00000020

W-06

autozero Value out of Range

0x00000040

W-07

autozero Fluctuation out of Range

0x00000000

no error/

alarm/

warning

Parameter for indication of actual and history errors, alarms and warnings