8. GENErAL SPECIFICATIONS

8-18

IM 01R04B05-00E-E 3rd edition July 30, 2010 -00

all Rights Reserved. Copyright © 2005, Rota Yokogawa

remote detector rCCS3, Option- Code :

Options

Option
code

description

restrictions

Hazardous area approvals

1)

/KS1
/FS1
/ES1
/uS1

atEX intrinsically safe approval
FM approval for uSa + Canada
IECEx intrinsically safe approval
InMEtRo intrinsically safe approval for Brazil

only with cable conduit ´a´

GoSt approval

1)

/QR1
/QR2
/QR3

Russian GoSt approval
Kazakh GoSt approval
uzbekistan GoSt approval

see page 8; not with /Lt
see page 8; not for RCCS39/XR; not with /Lt
see page 8; not for RCCS39/XR; not with /Lt

Dual Seal approval

/DS

/RD

Dual Seal approval (conform with anSI/ISa-12.27.01)

Rupture disk

only RCCS34 to 39/XR; only with /FS1; not with
process connection a5
only RCCS34 to 39/IR, preferable with /Ga, not
with /tx, mandatory if /DS + /Ga is selected

tag number

/BG

With customer specified tag number on name plate

max. 16 digits

Flange Facing

/Dn
/RJ

Flange with safety grooves acc. to En 1092-1 form D
Ring type Joint Flanges

only for D2 to D6; not HC
only for a3, a4, a5; not HC

Gas Measurement

/Ga

Gas measurement, special factory adjustments and settings

select affiliated RCCF31 with /Ga;
to be conform with anSI/ISa-12.27.01 select /RD

Low temperature version

/Lt

-200°C < t

medium

< 150°C

not RCCS30 to 33; not with /KS1, /FS1, /ES1,
/uS1, /Mt, /Ht, /t1, /t2, /t3, /QR1, /QR2, /QR3

Extended temperature range

/Mt

-70°C < t

medium

< 230°C

not RCCS30 to 33; always with /S2 or /tx;
remote cable RCCY033/034 recommended

High temperature version

/Ht

t

medium

up to 350°C

only with /tx; only RCCS34 to 39/IR;
remote cable RCCY033/034 recommended

Special Calibration

/K2

2)

/K4
/K5

2)

/K6

Custom 5 pts mass-/volume-flow calibration using water with factory certificate
(traceable to German national standards)
Density adjustment + thermal treatment; (accuracy: 0.001 g/cm³
Custom 10 pts mass-/volume-flow calibration using water with DKD certificate
(according En-17025:2005)
Density calibration with 3 different fluids incl. individual temperature compensation
with certificate (accuracy: 0.0005 g/cm³)

only RCCS31 to 39; not with /Ga

only RCCS32 to 39; not with /Ga; not with
sanitary options; only available if converter is
also ordered

Certificates

/P2
/P3
/P6
/P8
/H1

Certificate of compliance with the order acc. to En 1024:2004 -2.1
as /P2 + test report acc to En 1024: 2004 -2.2 (QIC)
Material certificate acc to En 1024: 2004 -3.1
Pressure test report measuring system
oil and fat free for wetted surface acc. to aStM G93-03 level C

Sanitary type

/SF1

/SF2
/Sa
/SE

Surface roughness Ra = 0.8 µm

as /SF1 + test report roughness of wetted parts
as /SF2 + 3a- declaration of conformity and 3a- mark
as /SF2 + EHEDG- certificate

only RCCS34 to 39/IR; only process connections
S2, S4, S8; see also restrictions in table 11

not with process connection S2
not with process connection S2

Mounting set

/PD

2 inch pipe mounting set

only RCCS30 to 33; not with /tx; recommended
for RCCS30

Housing Pressure test

/J1

Rupture pressure proof test and certificate:
60 bar (RCCS34, RCCS36), 40 bar (RCCS38), 10 bar (RCCS39, RCCS39/IR)

not for RCCS30 to 33 + RCCS39/XR

Customer insulation / Heating

/S2

terminal box on extension for high or low process temperature

not with /t1 ... /t3

Factory Insulating / Heating

/t1
/t2
/t3

Insulation
Insulation + Heat carrier heating
Insulation + Heat carrier heating with ventilation

not for RCCS39/XR
not for RCCS39/XR
not for RCCS39/XR

X-Ray Examination

/Rt

X-ray examination of flange welding

not with material HC

PMI Examination

/PM4

/PM6

PaMI test (4 test points: process connection inlet + outlet, flow divider inlet +
outlet)

3)

PaMI test (6 test points: process connection inlet + outlet, measuring tubes, flow
divider inlet + outlet)

3)

only RCCS30 to 33

not RCCS30 to 33

Dye Penetration test

/Pt

Dye penetration test of flange welding

Stainless steel cable gland

/BS

Cable gland stainless steel

Special order

/Z

Special design must be specification an extra sheet

1)

Select affiliated converter RCCF31 with the same approval type (e.g. atEX).

2)

Calibration order sheet must be delivered with the order. this is available on the Flow Center Page at Coriolis/RCCx3/technical Information.

3)

Measuring tube PaMI test is performed per delivery batch.

Advertising