A1.4.5.2 determining the output value, A-22 – Yokogawa RotaMASS 3-Series User Manual

Page 122

Advertising
background image

APPENdIX 1. LIST OF PArAMETErS FOr EACH BLOCK OF rOTAMASS

a-22

IM 01R04B05-00E-E 3rd edition July 30, 2010 -00

all Rights Reserved. Copyright © 2005, Rota Yokogawa

A1.4.5.2 determining the Output Value

the value of out.Value is determined as follows:

• For counting up
out = integration start value (0) + total
• For counting down
out = integration start value (totaL_SP) - total

For counting up, the out value is follows:
• out < totaL_SP - PRE_tRIP
==> out_tRIP = 0, Count_PtRIP = 0
• totaL_SP - PRE_tRIP <= out < totaL_SP
==> out_tRIP = 0, Count_PtRIP = 1
• totaL_SP <= out
==> out_tRIP = 1, Count_PtRIP = 1

For counting down, the out value is follows:
• PtRIP < out
==> out_tRIP = 0, Count_PtRIP = 0
• 0 < out <=PRE_tRIP
==> out_tRIP = 0, Count_PtRIP = 1
• out <= 0
==> out_tRIP = 1, Count_PtRIP = 1

out_tRIP(#14):0

out_PtRIP(#15):0

out_tRIP(#14):1

out_PtRIP(#15):1

Counting up starting from 0

• For counting up

PRE_tRIP(#31)

out_tRIP(#14):0

out_PtRIP(#15):0

out_tRIP(#14):0

out_PtRIP(#15):1

out_tRIP(#14):1

out_PtRIP(#15):1

• For counting down

Counting down starting from totaL_SP

PRE_tRIP(#31)

0

0

totaL_SP(#7)

totaL_SP(#7)

Fa0205.EPS

out_tRIP(#14):0

out_PtRIP(#15):1

total: total of integrated values. this value is
retained even if IntEG_tYPE is changed during
integration (in auto).

If out is rewritten in the Man mode, integration
starts with the value rewritten in Man mode after the
mode wa returned to auto.

the values out_tRIP and out_PtRIP are deter-
mined according to the correlation between out and
totaL_SP/PRE_tRIP.

note that the given conditions do not apply to the
following cases:
• If IntEG_tYPE is 5, 6 or 7, out_tRIP and

out_PtRIP always output "0".

• IF IntEG_tYPE is 1 to 3, occurrence of

autoRESEt (reset caused if the threshold is
exceeded) causes out_tRIP to hold "1" fir
five seconds.