Model-, suffix- and option-codes, Integral type rcct3, model- and suffix- code, Integral type rcct3, option- code – Yokogawa RotaMASS 3-Series User Manual

Page 69

Advertising
background image

8. GENErAL SPECIFICATIONS

8-15

IM 01R04B05-00E-E 3rd edition July 30, 2010 -00

all Rights Reserved. Copyright © 2005, Rota Yokogawa

MOdEL-, SUFFIX- ANd OPTION-COdES

Integral type rCCT3, Model- and Suffix- Code :

Model

Suffix Code

description

restrictions

RCCt34
RCCt36
RCCt38
RCCt39
RCCt39/IR
RCCt39/XR

nominal Value : 2.7 t/h = 45 kg/min
nominal Value : 10 t/h = 170 kg/min
nominal Value : 32 t/h = 533 kg/min
nominal Value : 100 t/h = 1670 kg/min
nominal Value : 250 t/h = 4170 kg/min
nominal Value : 500 t/h = 8340 kg/min

only with /HP

Power supply

-a
-D

90 - 264 V aC
24 V DC

Indicator direction

H1
H2
V0
n0

Detector installation horizontal, tubes down
Detector installation horizontal, tubes up
Detector installation vertical
Without indicator

recom. for liquid service
recom. for gas service /Ga

Cable conduit connection

M
a

M20 x 1, female thread with cable glands
anSI ½´´ nPt, female thread without cable glands

mandatory with /FF3

Process connection size

1)

23
01
02
04
05
06
08
10
12
15
20

¾´´
Dn 15, ½´´
Dn 25, 1´´
Dn 40, 1½´´
Dn 50, 2´´
Dn 65, 2½´´
Dn 80, 3´´
Dn 100, 4´´
Dn 125, 5´´
Dn 150, 6´´
Dn 200, 8´´

see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11

Process connection rating and style

1)

a1
a2
a3
a4
a5
D2
D4
D5
D6
J1
J2
S2
S4
S8
G9
t9

aSME flange class 150, process connection dim. + facing acc. aSME B16.5
aSME flange class 300, process connection dim. + facing acc. aSME B16.5
aSME flange class 600, process connection dim. + facing acc. aSME B16.5
aSME flange class 900, process connection dim. + facing acc. aSME B16.5
aSME flange class 1500, process connection dim. + facing acc. aSME B16.5
En flange Pn 16, process connection dim. + facing acc. En 1092-1 Form B2
En flange Pn 40, process connection dim. + facing acc. En 1092-1 Form B2
En flange Pn 63, process connection dim. + facing acc. En 1092-1 Form B2
En flange Pn 100, process connection dim. + facing acc. En 1092-1 Form B2
JIS flange 10K, JIS B 2220
JIS flange 20K, JIS B 2220
thread acc. DIn 11851
Clamp, process connection dimensions acc. DIn 32676
Clamp, process connection dim. acc. tri-Clover (tri-Clamp) and ½´´ Mini Clamp
G, female thread
nPt, female thread

see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11
see table 11

Material of wetted parts

1)

SL
HC

Stainless steel 316L (1.4404)
Hastelloy C-22 (2.4602)

only RCCt34 to 39/IR

1)

see selection table „Process connection and materials“ (table 11)

Integral type rCCT3, Option- Code :

Options

Option
code

description

restrictions

Fieldbus Communication

/FB
/LC1
/EE
/Bt3

Digital communication (Foundation Fieldbus protocol)
Provides a PID control function block
Provides software download capability
With customer specified tag number of FF- communication + node address in
converter

max. 32 digits software tag + node address ;
not with /PS

Hazardous area approvals

/KF3
/KF4
/FF3

/EF3
/EF4
/uF3
/uF4

atEX Flame proof converter + Intrinsic safe detector
atEX Flame proof converter + Intrinsic safe detector + Intrinsic safe fieldbus
FM approval for uSa + Canada, Flame proof converter + Intrinsic safe detector

IECEx Flame proof converter + Intrinsic safe detector
IECEx Flame proof converter + Intrinsic safe detector + Intrinsic safe fieldbus
InMEtRo Flame proof converter + Intrinsic safe detector
InMEtRo Flame proof converter + Intrinsic safe detector + Intrinsic safe fieldbus

with /HP for gas group IIB
with /HP for gas group IIB
only with cable conduit “a”; with /HP not for
groups a and B
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB
with /HP for gas group IIB

GoSt approval

/QR1
/QR2
/QR3

Russian GoSt approval
Kazakh GoSt approval
uzbekistan GoSt approval

see page 8
see page 8; not for RCCt39/XR; not with /HP
see page 8; not for RCCt39/XR; not with /HP

Dual Seal approval

/DS
/RD

Dual Seal approval (conform with anSI/ISa-12.27.01)
Rupture disk

only with /FF3; not with process connection a5;
not wit RCCt39/XR, preferable with /Ga,
mandatory if /DS+/Ga is selected

Advertising