Yokogawa DO202 2-Wire Dissolved Oxygen Analyzer User Manual

Page 15

Advertising
background image

IM 12J05C01-01E

GB3836.13-1997 "Electrical apparatus for

explosive gas atmospheres Part 13: Repair and

overhaul for apparatus used in explosive gas

atmospheres".

GB3836.15-2000 "Electrical apparatus for

explosive gas atmospheres- Part 15: Electrical

installations in hazardous area (other than

mines)" .

GB3836.16-2006 "Electrical apparatus for

explosive gas atmospheres- Part 16: lnspection

and maintenance of electrical installation (other

than mines)".

mA-HART® communication
A. Input

: Two wire system 4-20 mA

B. Power supply

: Nominal 24 volt DC loop powered

DO202G :

up to 40 volts

DO202S :

up to 31.5 volts

Note:

The transmitter contains a switched

power supply, drawing its energy

from the 0-4 mA section of the signal.

Consequently the 17 volt limit is

applied at 4 mA. The characteristic of

the unit is such that above about 7 mA

on the output, the terminal voltage can

drop to 14.5 volts without problem. (see

figure 2-2)

C. Transmission:

Isolated output of 4 to 20 mA DC.

D. Signal

: Maximum load 425Ω at 24 VDC.

(see fi gure 2-1)

Burn to signal failure acc.

NAMUR Recommendation NE43

(18.01.1994)

E. Operating range :

3.9 to 21mA

F. Communication

:

HART®, 1200 Baud, FSK modulated

on 4 to 20 mA signal

G. Configuration

: Local with 6 keys

H. Software :

Firmware based on Yokogawa stack.

I. Hardware :

JYokogawa HART® Modem F9197UB

J. Hand Terminal :

Rosemount HHT 275/375

K. Other Control systems

:

Yokogawa PRM, Rosemount AMS,

Siemens PDM

L. Output span

:

There are three output modes in which the output

span can be freely selected: ppm (mg Oxygen

per kg of water):

0 - 50 ppm with minimum span of 1 ppm; ppb

(mg Oxygen per 1000 kg of water): 0 - 1999 ppb

with minimum span of 25 ppb and % Saturation:

0 - 600 % with minimum span of 10 %

M. Cable specification

0.5 mm diameter or 24 AWG over maximum

length of 1500 m

N. DD specification

The DO202 Device Description is available

enabling communications with the Handheld

Communicator and compatible devices.

PROFIBUS-PA communications
A. Input signal:

Digital

B. Supply voltage:

9 to 32 V DC

C. Operating current:

26.0 mA

D. Operating values:

According to IEC 1158-2

E. Bus connection

:

Fieldbus interface base on

IEC1158-2 according to FISCO-

Model

F. Power supply:

Power supply is achieved depend-

ant on the application by means of

segment coupler

G. Data transfer:

According to PROFIBUS- PA

profile class B based on EN 50170

and DIN 19245 part 4

H. GSD file:

The actual file can be downloaded

from www.profibus.com Configu-

ration: Local with 6 keys

I. Software:

Firmware based on Siemens

DPC31 stack.

J. Hardware:

PC- or PCMCIA-interfaces from

Siemens

K. Other control: Siemens

PDM systems

L Electrical

connection:

Terminals acc. to IEC 1158-2

M. Fieldbus-cable-types:

Twisted and shielded two

wire cable according to

recommendation based on IEC

1158-2 Cable diameter: 6 to 12

mm (0.24 to 0.47 inch)

FOUNDATION FIELDBUS H1 communications
A. Input signal

: Digital

B. Supply voltage

: 9 to 32 V DC

C. Operating current

: 26.0 mA (base current)

D. Operating values

: According to IEC 1158-2

E. Bus connection

:

Fieldbus interface based on IEC

1158-2 according to FISCO-Model

F. Power supply:

Power supply is achieved

dependant on application by

means of segment coupler

G. Data transfer:

FF specification Rev. 1.4 Basic

device

H. Function blocks:

3 x AI, Transducer, Resource

I. Files:

Actual file can be downloaded from

our homepage

J. Configuration:

locally with 6 keys

K. Software:

National Instruments:

NI-FBUS configurator

2-4 General Specifications

mA