Yokogawa DA100 User Manual
Page 31
Advertising

IM DA100-01E
2-10
RS-422-A/RS-485
1
2
3
4
Switch1
Data length
Baud rate
ON
OFF
1
2
3
4
Switch2
four-wire/two-wire
Stop bit
Parity
ON
OFF
1
2
3
4
Switch3
Address (upper)
Minimum response time
ON
OFF
1
2
3
4
Switch4
Address (lower)
ON
OFF
Baud rate (No.1 to 3 of Switch1)
Baud rate
No.1
No.2
No.3
300
OFF
OFF
ON
600
OFF
ON
OFF
1200
OFF
ON
ON
2400
ON
OFF
OFF
4800
ON
OFF
ON
9600
ON
ON
OFF
←Default Setting
19200
ON
ON
ON
38400
OFF
OFF
OFF
Data length (No.4 of Switch1)
Data length
No.4
7
OFF
8
ON
←Default Setting
Parity (No.1 to 2 of Switch2)
Parity
No.1
No.2
None
OFF
OFF
ODD
OFF
ON
EVEN
ON
OFF
←Default Setting
Stop bit (No.3 of Switch2)
Stop bit
No.3
1
OFF
←Default Setting
2
ON
Switch between four-wire/two-wire systems (No.4 of Switch2)
four-wire/two-wire
No.4
four-wire
OFF
←Default Setting
two-wire
ON
2.4 Connecting the Interface Cables