· Insertion of noise filter and noise killer

If the influence from noise cannot be eliminated by the methods described before, use noise filter
or noise killer.
Power line noise rejection
Step 1 : Insert an isolation transformer into the power line.

Increasing impedance to high frequency

with shield, which is grounded

1:1

DA100

(Most of the noise is
high-frequency noise)

100V AC

Power
supply

Step 2 : Insert a power line noise filter (available on the market)

High frequency noise is divided by decreasing impedance to ground through C and
increasing impedance through L.

100V AC

L

C

Power
supply

DA100

Note 1:Ground the noise filter and DA100 in common.
Note 2:Since insertion of a noise filter increases the by-pass current (regarded as leakage

current), make sure that the leakage current is within the specified value.

· When the noise contains wide frequency components

While one-point grounding is effective at a low frequency, it sometimes forms a loop and has an
adverse effect on a high frequency.

Ex: Connecting a power meter and DA100 grounded at one point to an inverter

AC power meter

DA100

Noise source

(inverter, etc.)

High-frequency noise

(reverse flow)

One-point

grounding

AC power meter

DA100

Noise

blocking of reverse flow

Ferrite beads

(high impedance at high frequency)

Reverse flow of high-frequency to the DA100 is thus suppressed.

The power meter leaks the high-frequency noise component to the
ground and that noise flows back to the DA100 side.

Noise source

(inverter, etc.)

· Input noise rejection

If input noise cannot be rejected by means of one-point grounding or 100-ms integration, insert
capacitor or ferrite beads as they are effective in rejecting pulse noise.
Step 1 : Connect a capacitor between the L input and ground.

C

H

L

DA100

Use a capacitor from a hundred
to thousands of pF which can
withstand high voltages and
must be grounded.

Step 2 : Rejection of pulse noise when grounding is impossible.

C

H

L

DA100

Use a capacitor from a hundred
to thousands of pF.

Ferrite beads

Insert the ferrite beads as necessary.