Yokogawa DA100 User Manual

Page 75

Advertising
background image

IM DA100-01E

4-6

Communication Functions (the function of communication modules)

GP-IB, RS-232C, RS-422-A/RS-485, Ethernet

Input/Output Functions (the function of DI/DO modules)

2 alarm output, 1 fail output and 12 remote control input for only with /M1 option

Power Supply

Rated supply voltage
AC power supply: 100 to 240 VAC (free supply voltage selection)
DC power supply: 12 to 28 VDC
AC adapter (optional accessory): 100 to 240 VAC
Permitted supply voltage
AC power supply: 90 to 250 VAC
DC power supply: 10 to 32 VDC
AC adapter (optional accessory): 90 to 250 VAC
Rated supply voltage frequency
AC power supply: 50/60 Hz
AC adapter (optional accessory): 50/60 Hz
Maximum power consumption:

· DA100 Stand-alone type (with 6 modules connected):

in case of 100VAC input: max. 55VA
in case of 240VAC input: max. 70VA
in case of DC power supply: max. approx. 25VA
in case of AC adapter (100VAC input): max. 55VA
in case of AC adapter (240VAC input): max. 70VA

· DA100 Expandable type (with 4 modules connected):

in case of 100VAC input: max. 45VA
in case of 240VAC input: max. 55VA
in case of DC power supply: max. approx. 25VA
in case of AC adapter (100VAC input): max. 45VA
in case of AC adapter (240VAC input): max. 55VA

· DS400 Subunit (with 4 modules connected):

in case of 100VAC input: max. 45VA
in case of 240VAC input: max. 55VA
in case of DC power supply: max. approx. 25VA
in case of AC adapter (100VAC input): max. 45VA
in case of AC adapter (240VAC input): max. 55VA

· DS600 Subunit (with 6 modules connected):

in case of 100VAC input: max. 55VA
in case of 240VAC input: max. 70VA
in case of DC power supply: max. approx. 25VA
in case of AC adapter (100VAC input): max. 55VA
in case of AC adapter (240VAC input): max. 70VA
Fuse Rating (The fuse may not be replaced by the customer.)
Main Unit
AC power supply
Maximum rated voltage/current: 250 V/2 A, Type: Time-lag, Standard: IEC/VDE
DC power supply
Maximum rated voltage/current: 250 V/6.3 A, Type: Time-lag, Standard: UL/CSA
Subunit
AC power supply
Maximum rated voltage/current: 250 V/2 A, Type: Time-lag, Standard: IEC/VDE
DC power supply
Maximum rated voltage/current: 250 V/6.3 A, Type: Time-lag, Standard: UL/CSA

Normal Operation Conditions

Supply voltage

AC power supply: 90 to 250 VAC
DC power supply: 10 to 32 VDC
AC adapter (optional accessory): 90 to 250 VAC

Supply frequency

50Hz

±2%, 60Hz ±2%

4.1 DA100/ DS400/ DS600

Advertising