8 alarm output module, Alarm output module -24 – Yokogawa DA100 User Manual

Page 93

Advertising
background image

IM DA100-01E

4-24

4.8

Alarm Output Module

Type, Number of outputs, Contact mode, Terminal type

Contact mode

Transfer contact (NO-C-NC)

Make contact (NO-C)

screw

screw

Terminal type

Type

Number of

outputs

DT200-11

DT200-21

4

10

Style Number S1
Normal operating temperature/humidity

0 to 50

°C

20 to 80% RH for 0 to 40

°C, 10 to 50% RH for 40 to 50 °C (no condensation)

Output updating rate

every measurement interval

Contact mode

Make contact

: normal open/common contact type

Transfer contact

: normal open/common/normal close type

Activate/de-activate

switchable

Hold/non-hold

switchable

Reflash alarm

up to 6 contacts can be specified.

Contact capacity

250V DC/0.1A (with a resistor load)
250V AC/2A (with a resistor load)
30V DC/2A (with a resistor load)

Dielectric strength

Between the output terminal and ground: 2300V AC (50/60Hz) for one minute.

Power consumption

Included in the main unit or the subunit to which the module is to be installed.

External dimensions and weight

Weight(kg)

0.3

0.35

External dimensions(W)x(H)x(D) mm

approx.57

x

137

x

67.9

approx.57

x

137

x

67.9

Type

DT200-11
DT200-21