Yokogawa DA100 User Manual

Page 78

Advertising
background image

IM DA100-01E

4-9

4

Specifications

4.2 Universal Input Module and DCV/TC/DI Input

Module

Type, Number of Channels, Terminal Type and Minimum Measurement Interval

0.5s

0.5s

2s

2s

2s

2s

0.5s

0.5s

2s

2s

2s

2s

screw

clamp

screw

clamp

screw

clamp

screw

clamp

screw

clamp

screw

clamp

10ch

10ch

20ch

20ch

30ch

30ch

10ch

10ch

20ch

20ch

30ch

30ch

DU100-11

DU100-12

DU100-21

DU100-22

DU100-31

DU100-32

DU200-11

DU200-12

DU200-21

DU200-22

DU200-31

DU200-32

Kind

Universal

input

module

DCV/TC/DI

input

module

Type

Number of

channels

Terminal

type

Minimum measurement

interval

Style Number S1
Input method

floating unbalanced input, each channel mutually isolated (channel independent)
The RTD range has a common potential (terminal b)

A/D resolution

±20000

A/D integration time

20ms (50Hz), 16.7ms (60Hz), 100ms (10Hz) or auto
However, AUTO does not function if the instrument is the stand-alone DC power supply model,
or the subunit (DS400/DS600) of the DC power supply model. (Selecting “AUTO” will set the
A/D integration time to 20 ms (50 Hz)).

Minimum measurement interval

No. of
channels/
1 module

20ms/16.7ms

(50Hz/60Hz)

4s

5s

6s

3s

4s

4s

12s

15s

20s

10

20

30

*: 2s if the power monitor module is installed.

Low-pass filter OFF

Low-pass filter ON

Filter ON/OFF

A/D integration
time

0.5s*

2s

2s

100ms

(10Hz)

20ms/16.7ms

(50Hz/60Hz)

100ms

(10Hz)

Normal operating temperature/humidity

–10 to 60

°C

20 to 80% RH for –10 to 40

°C, 10 to 50% RH for 40 to 50°C, 5 to 30% RH for 50 to 60°C (no

condensation)

Compensation for the reference junction

Switchable internally or externally for each channel.

Compensation accuracy for the reference junction

(measured at 0

°C, where the input terminals are balanced)

Type R, S, B, W

:

±1°C

Type K, J, E, T, N, L, U :

±0.5°C

Maximum allowable input voltage

2V DC or lower range, TC, RTD, DI (CONT)

:

±10V DC

6V DC or greater range, DI (LEVEL)

:

±60V DC

Normal mode voltage

voltage, TC

: 1.2 times the rated range or less (at peak value, including 50 or 60Hz signal

component)

RTD

: 50 mV or lower (at peak value)

Normal mode rejection ratio

40dB or greater (50/60Hz

±0.1%)

Common mode noise voltage

250VAC rms (50/60Hz)

Common mode rejection ratio

120dB or greater (50/60Hz

±0.1%, 500Ω unbalanced, between the negative measurement terminal

and ground)

Maximum noise between channels

150VAC rms (50/60Hz)