2.2.2.1 Control connections SK CU4-PBR

The terminal bar of the customer unit SK CU4-PBR is divided into two potential levels.

Connection of up to 2 sensors is made on the terminal bar (terminals C1 and C2).

NOTE

Looping of the 24V supply voltage (terminals 40/44) is possible, however a maximum
current load of 2A for the SK CU4-PBR must not be exceeded.