NORD Drivesystems BU0220 User Manual

Page 22

Advertising
background image

PROFIBUS DP

– Supplementary manualfor NORD Frequency Inverter SK 2xxE

22

Subject to technical amendments

BU 0220 GB-0912

Control connection details

Terminal/

Name

Function

Data

Description / wiring suggestion

Parameter

44

24V

24V supply

(Module, field and system
bus level)

24VDC ±20%

≈ 90mA
reverse polarity protected

max. permissible current
load: 2A

Connection of supply voltage for
module and 24V source for supply
of the digital inputs (DIN1 and
DIN2)

-

40 GND / 0V

Reference potential
for digital signals

-

C1

DIN1

Digital input 1

(I/O PROFIBUS DP DIN1)

Low 0V ... 5V

High 15V ... 30V

R

i

= 8.1k

Input capacitance 10nF

Scan rate 1 ms

Each digital input has a reaction
time of 1ms.

Inputs as per EN 61131-2 Type 1

P174

C2

DIN2

Digital input 2

(I/O PROFIBUS DP DIN2)

P174

77

Sys H

System bus

data cable +

System bus
interface

-

78

Sys L

System bus

data cable -

-

40 GND / 0V

Reference potential
for digital signals

24VDC ±20%

≈ 90mA
reverse polarity protected

max. permissible current
load: 2A

Connection of supply voltage for
module and 24V source for supply
of the digital inputs (DIN1 and
DIN2)

-

44

24V

24V supply

(Module, field and system
bus level)

-

Potential isolation

82

PBR B

(incoming)

Bus +
(red lead)

RxD/TxD-P

RS485 transfer

The use of twisted, shielded two-
conductor cable / Type A Profibus
cable is highly recommended

-

81

PBR A

(incoming)

Bus -
(green lead)

RxD/TxD-N

-

46

GND/

0V BUS

Data ground bus

-

83

RTS

Ready to send

-

47

VO/

5V BUS

+5V bus supply
voltage

Internal Profibus voltage
supply

Note: Must not be used externally!

-

82

PBR B

(outgoing)

Bus
(red lead)

RxD/TxD-P

RS485 transfer

The use of twisted, shielded two-
conductor cable / Type A Profibus
cable is highly recommended

-

81

PBR A

(outgoing)

Bus
(green lead)

RxD/TxD-N

-

46

GND/

0V BUS

Data ground bus

-

Advertising