5 Parameterisation

BU 0220 GB-0912

Subject to technical amendments

49

Parameter

Setting value / Description / Note

Device

Supervisor

Parameter
set

P741

... [-01]

...

... [-10]

Process data bus Out

S

0000 ... FFFF (hex)

This parameter provides information about the actual status word and the actual values that are
transferred via the bus systems.

... [-01] = Status word

Status word

... [-02] = Actual value 1 (P543 [-01])

... [-03] = Actual value 2 (P543 [-02])

... [-04] = Actual value 3 (P543 [-03])

... [-05] = Bus I/O Out Bit (P481)

The displayed value depicts all Bus Out Bit sources
linked with or.

... [-06] = Parameter data Out 1

... [-07] = Parameter data Out 2

... [-08] = Parameter data Out 3

... [-09] = Parameter data Out 4

... [-10] = Parameter data Out 5

Data during parameter transfer.

P748

System bus status

0000 ... FFFF (hex)

or

0 ... 65535 (dec)

Shows the status of the system bus.

Bit 0:

Bit 1:

Bit 2:

Bit 3:

Bit 4:

Bit 5:

Bit 6:

Bit 7:

Bit 8:

Bit 9:

Bit 10:

24V Bus supply voltage

CANbus in "Bus Warning" status

CANbus in "Bus Off" status

Bus module is online

Additional module 1 is online

Additional module 2 is online

The protocol of the CAN module is 0 = CAN / 1 = CANopen

Vacant

"Bootup Message" sent

CANopen NMT State

CANopen NMT State

CANopen NMT State

Bit 10

Bit 9

Stopped
Pre-Operational
Operational

0
0
1

0
1
0

P749

DIP switch status

0000 ... 01FF (hex)

or

0 ... 511 (dec)

This parameter shows the actual setting of the FI DIP switch "S1" (See BU0200).

Bit 0:

Bit 1:

Bit 2:

Bit 3:

Bit 4:

DIP switch 1

DIP switch 2

DIP switch 3

DIP switch 4

DIP switch 5

Bit 5:

Bit 6:

Bit 7:

Bit 8:

DIP switch 6

DIP switch 7

DIP switch 8

EEPROM

– Memory module

(0=plugged in, 1= not plugged in)