5 Parameterisation

BU 0220 GB-0912

Subject to technical amendments

53

Parameter

Setting value / Description / Note

Device

Supervisor

Parameter
set

P176

... [-01]

...

... [-17]

Process data bus In

-32768 ... 32767

Bus data received from PROFIBUS DP master

… [-01] = Bus module outputs

… [-02] = Control word FI 1

… [-03] = Setpoint 1 for FI 1

… [-04] = Setpoint 2 for FI 1

… [-05] = Setpoint 3 for FI 1

… [-06] = Control word FI 2

… [-07] = Setpoint 1 for FI 2

… [-08] = Setpoint 2 for FI 2

… [-09] = Setpoint 3 for FI 2

… [-10] = Control word FI 3

… [-11] = Setpoint 1 for FI 3

… [-12] = Setpoint 2 for FI 3

… [-13] = Setpoint 3 for FI 3

… [-14] = Control word FI 4

… [-15] = Setpoint 1 for FI 4

… [-16] = Setpoint 2 for FI 4

… [-17] = Setpoint 3 for FI 4

P177

... [-01]

...

... [-17]

Process data bus Out

-32768 ... 32767

Bus data transmitted to PROFIBUS DP master

… [-01] = Bus module inputs

… [-02] = Status word FI 1

… [-03] = Actual value 1 for FI 1

… [-04] = Actual value 2 for FI 1

… [-05] = Actual value 3 for FI 1

… [-06] = Status word FI 2

… [-07] = Actual value 1 for FI 2

… [-08] = Actual value 2 for FI 2

… [-09] = Actual value 3 for FI 2

… [-10] = Status word FI 3

… [-11] = Actual value 1 for FI 3

… [-12] = Actual value 2 for FI 3

… [-13] = Actual value 3 for FI 3

… [-14] = Status word FI 4

… [-15] = Actual value 1 for FI 4

… [-16] = Actual value 2 for FI 4

… [-17] = Actual value 3 for FI 4