5 Parameterisation

BU 0220 GB-0912

Subject to technical amendments

43

Parameter

{Factory setting}

Setting value / Description / Note

Device

Supervisor

Parameter
set

P480

... [-01]

...

... [-12]

Function Bus I/O In Bits

0 ... 77

{ [-01] = 01 }

{ [-02] = 02 }

{ [-03] = 05 }

{ [-04] = 12 }

{ [-05...-12] = 00 }

The Bus I/O In Bits are perceived as digital inputs. They can be set to the same functions
(P420).

These I/O bits can also be used in combination with the AS Interface (SK 225E or SK 235E) or
the I/O extension (SK CU4-IOE or SK TU4-IOE).

… [-01] = Bus I/O In Bit 0

… [-02] = Bus I/O In Bit 1

… [-03] = Bus I/O In Bit 2

… [-04] = Bus I/O In Bit 3

… [-05] = Bus I/O In Bit 4

… [-06] = Bus I/O In Bit 5

… [-07] = Bus I/O In Bit 6

… [-08] = Bus I/O In Bit 7

… [-09] = Flag 1

… [-10] = Flag 2

… [-11] = Bit 8 BUS control word

… [-12] = Bit 9 BUS control word

The possible functions for the bus In bits can be found in the table of functions for the digital
inputs in parameter P420.

P481

... [-01]

...

... [-10]

Function Bus I/O Out Bits

0 ... 39

{ [-01] = 18 }

{ [-02] = 08 }

{ [-03] = 30 }

{ [-04] = 31 }

{ [-05...-10] = 00 }

The bus I/O Out bits are perceived as multi-function relay outputs. They can be set to the same
functions (P434).

These I/O bits can also be used in combination with the AS Interface (SK 225E or SK 235E) or
the I/O extension (SK CU4-IOE or SK TU4-IOE).

… [-01] = Bus I/O Out Bit 0

… [-02] = Bus I/O Out Bit 1

… [-03] = Bus I/O Out Bit 2

… [-04] = Bus I/O Out Bit 3

… [-05] = Bus I/O Out Bit 4

… [-06] = Bus I/O Out Bit 5

… [-07] =Flag 1

… [-08] = Flag 2

… [-09] = Bit 10 BUS status word

… [-10] = Bit 13 BUS status word

The possible functions for the Bus Out Bits can be found in the table of functions for the relay
P434.

P482

... [-01]

...

... [-08]

Standardisation of bus I/O Out bits

-

400 … 400 %

{ all 100 }

Adjustment of the limit values of the bus Out bits. For a negative value, the output function will
be output negative.

Once the limit value is reached and positive values are delivered, the output produces a High
signal, for negative setting values a Low signal.

P483

... [-01]

...

... [-08]

Hysteresis of bus I/O Out bits

S

1 … 100 %

{ all 10 }

Difference between switch-on and switch-off point to prevent oscillation of the output signal.

Advertising