4 Commissioning

BU 0220 GB-0912

Subject to technical amendments

37

Configuration steps

The following items must be configured in the planning of an SK CU4-

… or SK TU4-PBR(-M12) technology

unit:

PROFIBUS address

Setting the PROFIBUS DP with DIP switches (Section 2.2.3
"Configuration

")

Integration of the DP slave (technology

unit) on the PROFIBUS DP

Select the components from the catalogue and integrate
them into the PROFIBUS DP string.

The frequency inverters connected to

the technology unit must be defined

Specification of the frequency inverter designation and
allocation of the associated addresses / slot allocation.

Configuration of the DP slave

Assign the names and addresses

Selection of PPO types

Each frequency inverter must be assigned a PPO type
(parameterise on the appropriate slot)

Technology unit I/Os

For the use of additional technology unit I/Os, the Profibus
module I/O must be integrated into Slot 1 of the DP slave

4.2.1

DP slave slot assignment

The following slot assignments must be observed in the DP slave for the planning of frequency inverters:

Cyclic data traffic

The assignment of the input and output address ranges to the frequency inverters is made via the assignment
of the slot position.

Slot

Cyclic process data

transfer

Device

1

Profibus I/O Modules

Technology unit I/Os

2

PPO type 1 to 4

Frequency inverter 1

3

PPO type 1 to 4

Frequency inverter 2

4

PPO type 1 to 4

Frequency inverter 3

5

PPO type 1 to 4

Frequency inverter 4

Acyclic data traffic

The assignment of acyclic data packages to the individual frequency inverters and the technology unit is not
carried out via the slot position, but rather via Slot 0 and the relevant index (Table):

Index

Acyclic parameter

transfer

Device

100

only parameter data

Technology unit

101

only parameter data

Frequency inverter 1

102

only parameter data

Frequency inverter 2

103

only parameter data

Frequency inverter 3

104

only parameter data

Frequency inverter 4

Therefore no settings and configurations are required in the Hardware config. of the SIMATIC Manager are
necessary for the use of acyclic data traffic for the transfer of parameter data.