6 error monitoring and error messages, 1 error monitoring – NORD Drivesystems BU0220 User Manual

Page 55

Advertising
background image

6 Error monitoring and error messages

BU 0220 GB-0912

Subject to technical amendments

55

6 Error monitoring and error messages

6.1 Error monitoring

The majority of bus module and frequency inverter functions and operating data are continuously monitored
and simultaneously compared with limiting values. If a deviation is detected, the bus module or inverter reacts
with a warning or an error message.

For basic information, please refer to the relevant main manual of the frequency inverter.

Errors cause the frequency inverters to switch off, in order to prevent a device fault.

The following options are available to reset a fault (acknowledge):

1. Switching the mains off and on again,

2. by means of a correspondingly programmed digital input

(SK 200E: (P420) [-

…], function {12} or

SK 500E: (P420 ... P425), function {12}),

3.

By switching of the “enable” on the frequency inverter
(if no digital input is programmed for acknowledgement),

4. By Bus acknowledgement or

5. By P506, the automatic error acknowledgement.

Visualisation of the inverter error codes is made via the frequency inverter (see relevant manual).

Errors which are attributable to bus operation are visualised via the bus module. The precise error message is
displayed in parameter (P170).

NOTE

The display of a bus error is shown in the operating display of the SimpleBox SK CSX3H by
means of the error group number E1000. In order to obtain the precise error number, the
module information parameter P170 must be selected. The current error is shown in Array
[01] of this parameter; the last error is stored in Array [02].

The PROFIBUS DP module monitors the following functions:

Cyclic connection to bus master via the PROFIBUS DP watchdog function

(parameterisation is carried out in the bus master)

Cyclic connection to the bus master and valid control data via the bus module parameter (P151)

Advertising