2524UM

Super Frame configured, the remote alarm condition is signalled out
of band in the facility data link.

You can see if the FT1/T1 CSU/DSU is receiving a remote alarm (yel-
low alarm) by issuing the

show service-module

command.

To disable remote alarms, type this in interface configuration mode:

no service-module t1 remote-alarm-enable

Enable Loopcodes that Initiate Remote Loopbacks

To configure the remote loopback code used to transmit or accept CSU
loopback requests, and type this in interface configuration mode:

service-module t1 remote-loopback full

To configure the loopback code used by the local CSU/DSU to gener-
ate or detect

payload-loopback

commands, type this in interface

configuration mode:

service-module t1 remote-loopback payload

[alternate | v54]

Note:

By entering the

service-module t1 remote-

loopback

command without specifying any keywords,

you enable the standard-loopup codes, which use a 1-in-5
pattern for loopup and a 1-in-3 pattern for loopdown.

You can simultaneously configure the

full

and

payload

loopback

points. However, only one loopback payload code can be configured
at a time. For example, if you configure the

service-module t1

remote-loopback payload alternate

command, a pay-

load v.54 request, which is the industry standard and default, cannot b
transmitted or accepted. Full and payload loopbacks with standard-
loopup codes are enabled by default.

The

no

form of this command disables loopback requests. For exam-

ple, the

no service-module t1 remote-loopback full

command ignores all full-bandwidth loopback transmissions and re-
quests. Configuring the no form of the command may not prevent telco
line providers from looping your router in esf mode, because fractional
T1/T1 telcos use facilities data-link messages to initiate loopbacks.

If you enable the

service-module t1 remote-loopback

command, the

loopback remote

commands on the FT1/T1 CSU/

DSU module will not be successful.