4.3 THRMTRIP/TALERT

4.3.1

Thermal Trip – THRMTRIP

The thermal trip function is multiplexed on the GEVENT2 pin. The THRMTRIP status cannot be used to
generate SCI or SMI#.

Table 4-6: THRMTRIP Pin

Pin Name

Enable THRMTRIP

THRMTRIP
Polarity
Control

THRMTRIP Status

THRMTRIP#/
GEVENT2#/
SMBALERT#

PM IO Reg68h[Bit 3]=1
in addition PM IO
Reg55h[Bit 0]=1 to
enable shutdown

PM IO
Reg67h[Bit 6]
0=Active Low
1=Active High

PM IO
Reg54h[Bit 0]

4.3.2

Temperature Alert – TALERT

The temperature alert function is multiplexed on the GPIO64 pin. It can be programmed to generate SMI#,
SCI, or IRQ13 through GPE. It can also be programmed to generate SMI# without using GPE.

Table 4-7: TALERT# through GPE

Pin Name

TALERT# Enable

TAERLT#
Polarity
Control

TALERT# Status

TALERT# Outcome

TALERT#/
GPIO64/
TEMPIN3

AcpiGpe0Blk04[Bit 9]=1

PM IO
Reg67h[Bit 5]
0=Active Low
1=Active High

AcpiGpe0Blk00[Bit 9]

Controlled by
PM I/O Reg3Ch[Bit3:2]:
00= ACPI Event (SCI or SMI#,
depending on SCI_EN bit)
01= SMI#
10= N/A
11= IRQ13

Table 4-8: TALERT# to generate SMI#

Pin Name

TALERT# SMI# Enable

TAERLT#
Polarity
Control

TALERT# Status

TALERT# Outcome

TALERT#/
GPIO64/
TEMPIN3

IO C50h/C51h, index 03h
[Bit 1]=1

PM IO
Reg67h[Bit 5]
0=Active Low
1=Active High

IO C50h/C51h, index
02h [Bit 0]

SMI#