AMD SB600 User Manual

Page 61

Advertising
background image


©2008 Advanced Micro Devices, Inc.

OCHI USB 1.1 and EHCI USB 2.0 Controllers

AMD SB600 Register Reference Manual

Proprietary

Page 61

HcRhDescriptorA - 32 bits - [MEM_Reg : 48h]

Field Name

Bits

Default

HCD

HC

Description

NDP 7:0

02h

R

R

NumberDownstreamPorts

These bits specify the number of downstream ports
supported by the Root Hub.

PSM 8

0b

RW

R

PowerSwitchingMode
This bit is used to specify how the power switching of
the Root Hub ports is controlled. It is implementation-
specific. This field is only valid if the
NoPowerSwitching

field is cleared.

0: all ports are powered at the same time.
1: each port is powered individually. This mode
allows port power to be controlled by either the global
switch or per-port switching. If the
PortPowerControlMask

bit is set, the port responds

only to port power commands
(Set/ClearPortPowe

r). If the port mask is cleared,

then the port is controlled only by the global power
switch (Set/ClearGlobalPower).

NPS 9

1b

RW

R

NoPowerSwitching
These bits are used to specify whether power
switching is supported or port are always powered. It
is implementation- specific. When this bit is cleared,
the PowerSwitchingMode specifies global or per-
port switching.
0: Ports are power switched
1: Ports are always powered on when the HC is
powered on

DT 10

0b

R

R

DeviceType
This bit specifies that the Root Hub is not a
compound device. The Root Hub is not permitted to
be a compound device. This field should always
read/write 0.

OCPM 11

1b

RW

R

OverCurrentProtectionMode
This bit describes how the overcurrent status for the
Root Hub ports are reported. At reset, this field
should reflect the same mode as
PowerSwitchingMod

e. This field is valid only if the

NoOverCurrentProtection

field is cleared.

0: over-current status is reported collectively for all
downstream ports
1: over-current status is reported on a per-port basis

NOCP 12

0b

RW

R

NoOverCurrentProtection
This bit describes how the overcurrent status for the
Root Hub ports are reported. When this bit is cleared,
the OverCurrentProtectionMode field specifies
global or per-port reporting.
0: Over-current status is reported collectively for all
downstream ports
1: No overcurrent protection supported

Reserved 23:13

Reserved

POTPGT 31:24

02h

RW

R

PowerOnToPowerGoodTime
This byte specifies the duration HCD has to wait
before accessing a powered-on port of the Root Hub.
It is implementation-specific. The unit of time is 2 ms.
The duration is calculated as POTPGT * 2 ms.