PROBLEM

CHECK

ACTION

The paint mixer does not start.

if mixer attached to receptacle.

receptacle for voltage.

if front door is not closed.

POWER switch is in the ON

position and operating properly. The

EMERGENCY STOP button should

not be depressed.

6.3 amp fuse.

5 amp Slow-Blow fuse.

PCB connector.

may be a problem with printed circuit

board.

• Connect to power source.

• Contact electrician.

• Close the front door.

• Turn on POWER switch. Put the

EMERGENCY STOP button in the

ON position.

• Replace fuse.

• Replace fuse.

• Reestablish PCB connector.

• Call Customer Service.

• Replace printed circuit board.

The top plate does not move in a

downward direction.

loose/broken wire in the DC motor

cable.

START switch mechanism on the

control panel for a loose connection.

DC motor.

may be a problem with printed circuit

board.

• Reconnect loose wire or replace

broken wire.

• Tighten connections at the START

switch.

• Replace START switch mechanism.

• Using voltmeter, measure voltage at

DC motor or call Customer Service.

• Replace DC motor.

• Call Customer Service.

• Replace printed circuit board.

Troubleshooting

Troubleshooting

Using the chart below, locate the problem in the first column, then select the

probable cause to check and action to take from the next two columns. The

problems are arranged from the simplest to the most complex.
Where appropriate, refer to the Servicing and Repair section to correct the

problem.