Adjusting clamping force – Fluid Management 5G-HD Harbil 5-Gallon Shaker User Manual
Page 42
40 | Harbil 5G Mixer
Fluid Management Customer Service 1 . 800 . 462 . 2466
3.
Remove the wire from the upper left terminal of the shake relay.
4.
On the control board, set the adjustment switch to position number 2.
5.
Plug the power cord back into the electrical outlet.
6.
Assure that the E-Stop button is released and press the power ON switch.
7.
Press the UP button on the control box.
8.
Open the door and place the positioning spacer (P/N 24096) and gauge
(P/N 24124) on the bottom plate against the back lip as shown.
Figure 12. Gauge Position
Note: Position is critical. Use the positioning spacer. Be sure the
gauge is centered and 4-5/8” from the back lip.
9.
Press the START button. The top plate will clamp the gauge without going
into the shaking cycle.
•
WARNING
If wire was not removed in step #3, the mixer will
shake, possibly causing damage or injury.
Adjusting Clamping Force
Bottom Plate
4-5/8”
Positioning
Spacer
Gauge
Back Lip