Troubleshooting – Fluid Management 5G-HD Harbil 5-Gallon Shaker User Manual
Page 26
24 | Harbil 5G Mixer
Fluid Management Customer Service 1 . 800 . 462 . 2466
PROBLEM
CHECK
ACTION
An excessive amount of vibration
occurs.
mixer is out of balance.
adjustable leg is broken or
damaged.
broken strut.
• Level by adjusting the legs.
• Replace adjustable leg.
• Replace broken strut.
START light is on and nothing
happens.
DC motor coupling set screw is
loose.
broken wire in the DC motor cabling.
problem with the DC motor.
may be a problem with printed circuit
board.
• Tighten the DC motor coupling set
screw.
• Replace DC motor cable.
• Replace DC motor.
• Call Customer Service.
• Replace printed circuit board.
START light is on and the top plate
clamps on the container, but mixer
will not run.
make sure that the mixer is on a
dedicated line.
if front door closed.
problem is a loose motor coupling
set screw.
reset button.
loose or broken wire in the shake
motor cabling.
shake motor.
• Connect to dedicated line.
• Close the door.
• Tighten DC motor coupling set
screw.
• Press blue reset button located on
overload relay.
• Tighten or replace wire.
• Replace shake motor cabling if
necessary.
• Replace wire.
• Contact Customer Service for
assistance.
• Replace the shake motor.
The mixer starts slowly and then
increases to normal speed in a few
seconds.
shake motor V-belt tension.
• Adjust the shake motor V-belt
tension.
Troubleshooting