Troubleshooting – Fluid Management 5G-HD Harbil 5-Gallon Shaker User Manual

Page 25

Advertising
background image

Fluid Management Customer Service 1 . 800 . 462 . 2466

Harbil 5G Mixer | 23

Troubleshooting

PROBLEM

CHECK

ACTION

The top plate does not move in an

upward direction.

voltage at the DC motor.

broken wire in the DC motor cabling.

problem with the DC motor.

problem with the UP switch

mechanism on the control panel.

may be a problem with printed circuit

board.

• Use voltage meter or contact

Customer Service for assistance.

• Replace broken DC motor cabling.

• Contact Customer Service.

• Replace DC motor.

• See wiring schematic and test with

voltmeter.

• Replace the UP switch mechanism.

• Call Customer Service.

• Replace printed circuit board.

Paint mixer runs before the top plate

clamps on the container.

binding of the top plate.

may be a problem with printed circuit

board.

• Clean and oil lead screws.

• Call Customer Service.

• Replace printed circuit board.

Paint mixer will not shut off.

timer control on the front control

panel.

if relay is stuck in the closed

position.

bad timer.

may be a problem with printed circuit

board.

• Replace if necessary.

• Replace relay.

• Replace timer.

• Call Customer Service.

• Replace printed circuit board.

The shake motor has voltage and

hums, but it will not run.

low line voltage.

V-belt tension.

motor capacitor.

shake motor.

• Confirm that the mixer is on a

dedicated line.

• Correct tension.

• Replace motor capacitor.

• Replace shake motor.

Advertising