Fluid Management Customer Service 1 . 800 . 462 . 2466

Harbil 5G Mixer | 41

10.

After clamping, read and record the force on the gauge.

11.

Place the power switch in the OFF position, wait about 5 seconds and return

it to the ON position.

12.

Press the UP button.

13.

If the force is at the lower limit or less, change the adjustment switch to the

next lowest number and go to step #9.

Note: If the force is at the “upper limit” or greater, change the

adjustment switch to the next highest number and go to

step #9. If the force falls within the target, go to the next

step.

14.

Press the power OFF switch.

15.

Remove the gauge and spacer.

16

. Unplug the power cord from the electrical outlet.

17.

Place the wire back on the upper left terminal on the shake relay.

18.

Close the control box and insert the screws.

19.

Plug the power cord into the electrical outlet.

At this point, the mixer is ready for normal operation.

Adjusting Clamping Force