Removing circuit board – Fluid Management 5G-HD Harbil 5-Gallon Shaker User Manual
Page 37
Fluid Management Customer Service 1 . 800 . 462 . 2466
Harbil 5G Mixer | 35
Read all of the following instructions. If you have any doubt about performing these
procedures, please contact Customer Service at Fluid Management.
Turn to the Parts Section for component identification and location.
•
WARNING
ELECTRICAL HAZARD
The mixer must be unplugged before attempting this
procedure. There is a chance of electrical shock.
Removing Circuit Board Procedure
1.
Unplug the electrical cord.
2
. Remove the sheet metal screws on the control panel and slowly swing it
down.
3
. Remove the push-on type connector at the bottom of the printed circuit
board.
Pull the connector with alternating left and right force away from the circuit
board. It is not necessary to loosen the screws on the connector.
4.
Remove the 4 nuts from the screws that attach the circuit board to the
control panel.
5.
Install the new board with the push-on connector.
6.
Reinstall the control panel and the top cover.
7.
Connect the electrical cord.
Removing
Circuit Board
Removing Circuit Board