Removing Circuit Board Procedure

1.

Unplug the electrical cord.

2

. Remove the sheet metal screws on the control panel and slowly swing it

down.

3

. Remove the push-on type connector at the bottom of the printed circuit

board.

Pull the connector with alternating left and right force away from the circuit

board. It is not necessary to loosen the screws on the connector.

4.

Remove the 4 nuts from the screws that attach the circuit board to the

control panel.

5.

Install the new board with the push-on connector.

6.

Reinstall the control panel and the top cover.

7.

Connect the electrical cord.