15

www.2n.cz

2.1.5. Internal lines

Pulse #. The digit replacing the tone hash on pulse telephones.

Pulse *. The digit replacing the tone asterisk on pulse telephones.

Time for 1

st

dialling. Defines the maximum time waiting for the first number to

be dialled after phone is picked up. The line gets the engaged tone after this
time period has elapsed.

Time for further dialling. Defines the maximum time spent waiting for the next

number to be dialled from an internal line. After it has lapsed the engaged tone
is heard and the call is cancelled.

Crossing Time to failure loop. Defines the time period before the engaged

tone is sent following unsuccessful dialling. After the line goes to a fault loop.

Bad dial key protection. The time period for which the next digit dialled is

ignored after dialling the entire number. It serves to prevent inadvertent call
back after unsuccessful dialling.

Switching on lock. The time the intercom lock is fastened.

Regime supervisor is valid. The time period for which the supervisor services

can be called upon after logging in to the Supervisor service

Ticking after attach. The time for which a ticking can be heard on the call after

connecting. After this period the service cannot be disconnected from the call.

Back to forwarder. The time the PBX tries to get a connection after

reconnecting with a hung up line. After this time it carries on in getting a
connection but it also starts ringing back to the switcher.

Back to operator. If the target user does not pick up the phone in this period

the ringing goes back to the operator.

End of switching over. After this period the PBX considers the call as dead.

The caller is told this by a voice telling them that all lines are unavailable and
the call is cancelled.

Ringing of holding CO. The time between being notified by tinkling on an

internal line that an external call is on hold.

End of holding. The time limit for a temporarily held external line to be hung

up.

Time of back ringing. The time call back lasts for.

Length of alarm ringing. The time the alarm will ring after activating it on an

internal line.

Delay from front. The time when a new incoming call is not accepted after

having been hung up.

Increasing of DTMF resistant for DISA. Min. length of the DTMF sign that is

accepted in the DISA direct inward calling.

Increasing of DTMF resistant for VMail. Min. length of the DTMF sign that is

accepted in VoiceMail.

Trace key system phone L2 – enable writing of key system phone layer 2

events into LogSystem listings. To read the data push the ‘dollar’ button on the
main bar of the configuration tool while reading accounting data, for example.

Trace key system phone ringing – enable writing of key system phone ringing

into LogSystem listings. To read the data push the ‘dollar’ button on the main
bar of the configuration tool while reading accounting data, for example.