Omega lite configuration instrument – 2N Omega Lite - Configuration Tool manual v1.6 User Manual

Page 51

Advertising
background image

2N

®

- OMEGA Lite

Configuration instrument


User’s manual – configuration instrument

51

www.2n.cz

•

Block Out – only an incoming external line and it cannot be entered on in the

outgoing direction

•

Auto TEI

•

Without authorisation – checks on authorisation not made on this line

•

Private – a line connected to a private network to which charging is not done

•

Receive overlap dialling – only for special PTMP applications

•

Send CLIP – it is possible to forward the caller’s CLIP to a private ISDN line.

•

Synchronising PBX time – during an outgoing call the PBX time is

synchronised with the ISDN operator’s time (if the operator provides this)

•

Fax line – labelling an ISDN fax line. Calling is with 3.1 audio signalling.

•

Prefix- a 4-digit prefix, which is automatically chosen as the first (DID through a

superior PBX) after engaging a line. The prefix is not recorded in the charging
row.

•

Min. time for accounting – the period deducted from the call time for

temporary charging

•

Priority – an internal line must have higher or the same priority so that it can

use this external line.

•

Series

1-8

– fill in the series number or numbers (incoming series number without

DID numbers or leave the series empty – if the ISDN network operator only
sends a DID number, for precise information ask the operator of the ISDN
network)

•

MSN – the line in the PTMP connection

•

MSN

1-8

– fill in the MSN number 1 to 8

•

Main group – dividing up the MSN numbers into two groups for the option of

switching to the DAY/NIGHT regime and other functions related to group 1 / 2.

•

Deactivating 2

nd

layer – by authorising it deactivates the second ISDN layer

after setting the time.