Omega lite configuration instrument – 2N Omega Lite - Configuration Tool manual v1.6 User Manual

Page 69

Advertising
background image

2N

®

- OMEGA Lite

Configuration instrument


User’s manual – configuration instrument

69

www.2n.cz


2.7.2. Switches, Broadcast, Tape Recorder


Enter the port relay for Activate temporary/permanent switch for groups PBX 1

and 2.

Temporary – activate the switch temporarily = default #85 (the relay is closed

until the dialling timeout expires = 15s, the activation is terminated immediately
by hang-up). If this item is empty, you can enter the required port relay after
dialling the service.

Permanent – activate the relay permanently = default #83 (the relay is closed

permanently and can be opened using the Deactivate permanent switch service
= default #84). If this item is empty, you can enter the required port relay after
dialling the service.

Assign AUX group to Broadcast and Tape recorder

Broadcast

- the selected AUX ports of the selected AUX group will be used

for the Broadcast=default #20 service at relax and for the Announce through
Broadcast
service in the ringing table.

Tape recorder - the selected AUX ports of the selected AUX group will be used

for the Switch on tape recorder=default #20 service during a call and also
automatically with every call of the extension for which the Switch on tape
recorder
service is selected in the Subscriber lines/Service enable /Activation
menu.


Assign the AUX ports into groups in the Global data/AUDIO groups menu.

Advertising