61

www.2n.cz

or until the incoming ringing from an external line

DISA

Number of voice from

1 to 10 = 0

Or nothing

Stops previous ringing to internal lines and

takes an external line to wait for a fax or

modem call or DTMF number

DISA End

None

Ends dialling detection

Voice

Number of voice from

1 to 9

Plays the voice

Select tone

A selection of tones

After lifting an external line with the DISA

service activated a different tone can be

imposed (for special applications)

Table

Number of ringing table

Ringing tables can be catenated

Automatic

operator

Automatic operator’s

number 0-8

Rings a given automatic operator voice

system. If module not working then it carries

on with next row in table.

Connect remote

access

None

Rings the remote access modem in the PBX.

If the module is not installed then it carries on

with next row in table.

Transit DID

VL, SYS number or

virtual

Carries out a start up on the bundle for

outgoing lines to the VTS by parameter. This

allows an outgoing call to be made from

within the PBX on the line account given by

the parameter.

Call fast dialling

The number or name of

the joint fast dialling

After an incoming external call it dials the

given fast dialling. Which line the call will be

charged to and which lines it will go to the

VTS is determined in the settings External

lines/Identification for transit calls.

Hang up

None

Hangs up on an external line and ends all

actions. It is in the last row and cannot be

removed.

Go to line

Row number

Jumps to the selected ringing table row.

Announce

through

broadcast

Voice message

Connects the AUX assigned to the

Broadcast service, plays the voice message

and the AUX Broadcast remains connected

until hang-up or the Terminate broadcast

service activation.

GSM DTMF test

None

While calling to a module equipped with

DTMF detectors (designated as OL2GSMD,

OLGFAX at 2N), you can dial the DTMF

characters during ringing that are displayed

on the PBX.

Attention: The total number of rows in all of the ringing tables cannot exceed 500.