Omega lite configuration instrument – 2N Omega Lite - Configuration Tool manual v1.6 User Manual

Page 18

Advertising
background image

2N

®

- OMEGA Lite

Configuration instrument


User’s manual – configuration instrument

18

www.2n.cz

-2

nd

Frequency = Amplitude to 31

-3

rd

Frequency = Amplitude to 21

Generator 1 (sine 1)

-Default frequency 425 Hz.

Generator 2 (sine 2)

-Example of forming a “British tone”.

Amplitude of the voice modules
The default value is set at 64 and it is not recommended to change it.

Busy tone detector parameters

Count of CPT periods

-minimum count of tones (beeps) according to

ITU-T E.180 before hang-up;
Silence fluctuation

-intensity of the silence signal (0-65535).

Jitter period

-tone duration tolerance against silence, starting from

tone:silence = 1:1 [ms];
CPT detection threshold behind filter

-minimum tone level (0-255) for the tone to

be considered present.


2.1.7. Parameters for voicemail

Voicemail

a line (or department) to which the modem of a voice

system is connected, Audio lines (Kerio VoiceMail) and the
ITS voice system lines.

Identification of mailbox

selection prefix before the identification sign (the

default setting is a pause of 1s).

DTMF for call clear return from being put through (called subscriber is

engaged)

Increasing of DTMF resistant for VMail. Min. length of the DTMF sign that is
accepted in VoiceMail.

Use protocol ITS

permission/prohibition for the voice mail ITS

Use protocol 602

permission/prohibition for the voice mail SW602



2.1.8. Authorisation numbers

Tables A, B, C, D, E, F for programming authorisations. Tables A, B, C, D

are prohibitive and conversely tables E and F are for exemptions and have greater
priority. Every table has 16 rows. Local numbers up to 5 digits can be entered into
tables A and B, the rest take ten digits.

Apart from the numbers it is also possible to add the sign “?”, which presents

all numbers (0-9).