Row unit mounted disc furrower, Row unit mounted bed leveler, Row unit mounted no till coulter – Kinze 3600 Lift and Rotate Planter Rev. 7/14 User Manual

Page 130: Row unit mounted disc furrower -22, Row unit mounted bed leveler -22, Row unit mounted no till coulter -22

Advertising
background image

M0236-01

Model 3600

6-22

Rev. 7/11

TM

Lubrication and Maintenance

ROW UNIT MOUNTED DISC fURROWER

Lubricate bushings in support arm mounting bracket at
frequency indicated in Lubrication of this section. Check each
bolt for proper torque. If bolt is loose, it should be removed and
bushing inspected for cracks and wear. Replace bushings as
necessary.

NOTE: Use only hardened flat washers. Replace damaged
flat washers with proper part. Torque bolts to 130 ft-lb
(176.2 N-m).

Blade hubs are equipped with sealed bearings. Replace
bearings if a bearing sounds or feels rough when wheel is
rotated.

Row unit mounted disc furrower

Replace solid or notched 12" diameter blades when worn to 11".

ROW UNIT MOUNTED BED LEVELER

Lubricate bushings in mounting bracket and links at frequency
indicated in Lubrication of this section. Check each bolt for
proper torque. If bolt is loose, it should be removed and
bushing inspected for cracks and wear. Replace bushing if
necessary.

NOTE: Use only hardened flat washers. Replace damaged
flat washers with proper part. Torque bolts to 130 ft-lb

(176.2 N-m).

Row unit mounted bed leveler

ROW UNIT MOUNTED NO TILL COULTER

Check nuts and hardware periodically for proper torque. Be sure
coulter is positioned square with row unit and aligned in front of
row unit disc opener.

NOTE: Torque ⅝" spindle hardware to 120 ft-lb (162 N-m).

Coulter blade can be adjusted to one of four settings. Initially
blade is set in highest position. As blade wears it can be adjusted
to one of three lower settings. See “Row Unit Mounted No Till
Coulter” in Row Unit Operation section of this manual.

Replace 16" diameter coulter blade when worn to 14½".

Row unit mounted no till coulter

Advertising