Kinze 3600 Lift and Rotate Planter Rev. 7/14 User Manual

Page 140

Advertising
background image

M0236-01

Model 3600

6-32

Rev. 7/11

TM

Lubrication and Maintenance

TM

6. Loosen four cap mounting nuts and remove pad holder cap.

7. Loosen pad hex jam nuts, back pad bolts out, and remove four pad holder assemblies. Remove old pads and

install new pads.

NOTE: Apply a small amount of weather stripping adhesive to hold pads in place during installation.

8. Reinstall pad hold assemblies in center section.

Removing pad holder assembly

New pads in pad holder assembly

NOTICE

Over tightening wear pads will cause premature wear and excessive
hydraulic lift pressures. Torque wear pads to 10 ft-lb (13.6 N-m). Do
not over tighten wear pads.

9. Tighten pad adjusting bolts, back off, and then torque wear pads to 10 ft-lb (13.6 N-m). Hold adjusting bolt from

turning and torque hex jam nuts to 200 ft-lb (271.1 N-m).

10. Reinstall cap and tighten cap mounting nuts.

11. Reinstall hydraulic hose, fittings, and safety hook.

12. Adjust stop on safety hook to 1⁄4"-3⁄8" clearance.

13. Rotate cam roller against front guide and tighten to 110 ft-lb (149.1 N-m). Make sure gap between roller guide

and center frame are equal on both sides. Raise planter out of roller guides and lower back down into roller

guides to be sure roller guides operate smoothly. Adjust rotation cylinder rod as needed.

14. Reset row unit down pressure and other attachments from Step 3.

Adjust safety hook clearance to 1⁄4"-3⁄8"

Adjust and tighten cam roller

Advertising