Page 104: Operating mode, Introduction, Disconnecting paths, Safety engineering, Danger

Advertising
background image

Safety engineering

Operating mode
Introduction

8

l

104

EDS84DG752 EN 4.0

8.4

Operating mode

8.4.1

Introduction

Due to safety option 10, the following safety functions can be used:

ƒ

Safe torque off (STO),
formerly: safe standstill

If requested, the safe disconnection of the drive is achieved through:

ƒ

Directly connected active sensors

ƒ

Passive sensors connected to a safety switching device

The safety functions are suitable for applications according to IEC 61508 to SIL 3 and
achieve a performance level (PL) e and the control category 4 according to EN ISO 13849−1.

}

Danger!

If the request for the safety function is cancelled, the drive will restart
automatically.
You must provide external measures which ensure that the drive only restarts
after a confirmation (EN 60204).

8.4.2

Disconnecting paths

The transmission of the pulse width modulation is safely switched (off) by the safety unit.
After this, the power drivers do not generate a rotating field. The motor is safely switched
to torqueless operation (STO).

M

SO

PWM

µC

µC

P

C

3x

3x

Xxx

E84DPSO02

Fig. 8−1

Operating principle of safety unit

SO

Safety option 10

xxx

Control terminals of the safety system or safety bus

C

Control section

mC

Microcontroller

PWM

Pulse width modulation

P

Power section

M

Motor