Technical data
General data and operating conditions
l
30
EDS84DG752 EN 4.0
Control
Control modes
VFCplus:
l
V/f control (linear or square−law)
SLVC:
l
Sensorless vector control (speed)
VFCplus eco:
l
Energy−efficient V/f control
Switching frequency
4 kHz, 8 kHz, 16 kHz,
Torque behaviour
Maximum torque
1.5 x M
rated
for 60 s
2.0 x M
rated
for 3 s
if rated motor power = rated controller power
Setting range
1 : 10
SLVC: In speed range 3 ... 50 Hz
V/f: In speed range 10 ... 50 Hz
Sensorless vector control (speed)
Minimum output
frequency
0.5 Hz (0 ... M
rated
)
Accuracy
±0.5 %
In the speed range 3 ... 50 Hz
Smooth running
±0.1 Hz
Output frequency
Range
−300 Hz ... +300 Hz
Absolute resolution
0.2 Hz
Standardised
resolution
Parameter data: 0.01 %, process data: 0.006 % (= 2
14
)
Digital setpoint selection
Accuracy
±0.01 %
Analog setpoint selection
Accuracy
±2 %
Relating to final value