Technical data

General data and operating conditions

4

l

30

EDS84DG752 EN 4.0

Control

Control modes

VFCplus:

l

V/f control (linear or square−law)

SLVC:

l

Sensorless vector control (speed)

VFCplus eco:

l

Energy−efficient V/f control

Switching frequency

4 kHz, 8 kHz, 16 kHz,

Torque behaviour

Maximum torque

1.5 x M

rated

for 60 s

2.0 x M

rated

for 3 s

if rated motor power = rated controller power

Setting range

1 : 10

SLVC: In speed range 3 ... 50 Hz
V/f: In speed range 10 ... 50 Hz

Sensorless vector control (speed)

Minimum output
frequency

0.5 Hz (0 ... M

rated

)

Accuracy

±0.5 %

In the speed range 3 ... 50 Hz

Smooth running

±0.1 Hz

Output frequency

Range

−300 Hz ... +300 Hz

Absolute resolution

0.2 Hz

Standardised
resolution

Parameter data: 0.01 %, process data: 0.006 % (= 2

14

)

Digital setpoint selection

Accuracy

±0.01 %

Analog setpoint selection

Accuracy

±2 %

Relating to final value