Technical data

Power terminals

Mains connection

4

l

45

EDS84DG752 EN 4.0

4.6.1

Mains connection

Pin / name

Features

Rated value

L1, L2, L3

Mains phases

according to rated data

assigned X1:
+

Earthing, 2 x in the Wu

4.6.2

Motor connection

Pin / name

Features

Rated value

U, V, W

Motor phases

according to rated data

assigned X1:
+

Earthing, 2 x in the Wu

4.6.3

Motor temperature monitoring

Pin / name

Features

Rated value

T1, T2

Motor temperature monitoring

according to rated data

4.6.4

Motor holding brake connection

Pin / name

Feature

Rated value

BD1 (+)
BD2 (−)

Connection of a motor holding brake
Output voltage
(depending on mains voltage)

AC 400 V

DC 180 V

AC 480 V

DC 215 V

Max. output current

0.3 A

Max. output power

55 VA

Time−dependent behaviour

See software manual, chapter "Holding brake
control/parameter setting"

Short−circuit strength

No

Reset and switch−on behaviour

Outputs are switched off

Operating frequency

Max. 30/min

4.6.5

Connection of brake resistor

Pin / name

Features

Rated value

Rb1, Rb2

Brake resistor

according to rated data