Commissioning

Quick commissioning

General configuration settings

6

l

77

EDS84DG752 EN 4.0

6.2.1

General configuration settings

For initial commissioning, settings can be made via DIP switch and potentiometer. The
settings must be made before mounting the drive unit since the setting elements cannot
be accessed from the outside.

Setting elements 0.37 ... 3 kW

The setting elements are located on the inner side of the drive unit.

Settings carried out via DIP1, DIP2, P2, P3, and P1 must be activated with DIP1/1. The
settings are accepted again at every mains connection. Thus, changes on parameters made
in the meantime may be overwritten.

0.37 ... 3 kW

E84DG041

E84DG044

Name

DIP1

Switch for basic setting of quick commissioning

DIP2

P1

Setting "Top Cover: Speed ... %"

P2

Setting "Speed ... %", (speed)

P3

Setting "Ramp ... s", (acceleration/deceleration time)

X70

Connection for USB diagnostic adapter E94AZCUS or diagnosis terminal

0

LED status display