Commissioning – Lenze 8400 motec Manual User Manual
Page 78
![background image](/manuals/565652/78/background.png)
Commissioning
Quick commissioning
General configuration settings
l
78
EDS84DG752 EN 4.0
Setting elements 4 ... 7.5 kW
The setting elements are located on the top of the drive unit.
ƒ
Provide for isolation from supply and secure to prevent a restart.
ƒ
Remove small cover on the top.
Settings carried out via DIP1, DIP2, P2, P3, and P1 must be activated with DIP1/1. The
settings are accepted again at every mains connection. Thus, changes on parameters made
in the meantime may be overwritten.
4 ... 7.5 kW
E84DG083
Name
DIP1
Switch for basic setting of quick commissioning
DIP2
P1
Setting "Top Cover: Speed ... %"
P2
Setting "Speed ... %", (speed)
P3
Setting "Ramp ... s", (acceleration/deceleration time)
X70
Connection for USB diagnostic adapter E94AZCUS or diagnosis terminal
0
LED status display