6 electrical installation, Electrical installation, Safety engineering – Lenze 8400 motec Manual User Manual
Page 108
Advertising
![background image](/manuals/565652/108/background.png)
Safety engineering
Electrical installation
l
108
EDS84DG752 EN 4.0
8.6
Electrical installation
X61 − connection of safety system "Safety Option 10"
Pin
Connection
Description
DO
SIB GI
SIA
X61
24O
DC 24 V
(+19.2 … +28.8 V)
+
-
"
Terminal strip, 5−pole
E84DG027
SIA
Safe input, channel A
SIB
Safe input, channel B
GI
GND potential for SIA/SIB
GND potential for the unsafe signalling output
24O
24 V voltage supply for the unsafe signalling output
DO
Unsafe signalling output: "SafeTorqueOff" with a 2−channel
request by SIA andSIB
X61
E84DG025
X61
a
[mm]
[mm
2
]
[AWG]
Safety
55
0.5 ... 1.5
20 ... 16
0.5 ... 1.0
20 ... 18
0.5
20
)
Note!
The wiring connected for test purposes to the connections of the safety system
must be removed (e.g. bridges SIA/SIB at 24O).