Commissioning, Handling of the keypad – Lenze 8400 motec Manual User Manual

Page 85

Advertising
background image

Commissioning

Handling of the keypad

6

l

85

EDS84DG752 EN 4.0

User menu

The user menu can be freely configured in C00517 and contains the following parameters
in the Lenze setting:

Parameter

Name

Info

Lenze setting

Value

Unit

C00002/19 Device command:

Reset error

After resetting the current error, further errors may be
pending which must be reset as well.
Details of the current error are displayed in C00166.

0

C00007

Control mode

Selection of how the application is to be controlled.

10

C00011

Appl.: Reference
speed

Setting the reference speed

1500

rpm

C00012

Accel. time − main
setpoint

FB L_NSet_1: Acceleration time of the ramp generator
for the main speed setpoint

2.0

s

C00013

Decel. time − main
setpoint

FB L_NSet_1: Deceleration time of the ramp generator
for the main speed setpoint

2.0

s

C00015

VFC: V/f base
frequency

V/f base frequency for VFCplus motor control

50

Hz

C00016

VFC: Vmin boost

Boost of the V/f voltage characteristic within the
range of low speed or frequency values for the
VFCplus motor control.

2.6

%

C00022

Imax in motor mode Maximum current in motor mode for all motor control

modes

5.8

A

C00039/1

Fixed setpoint 1
(L_NSet_1 n−Fix)

FB L_NSet_1: Fixed speed setpoints (JOG values) for
the setpoint generator
Fixed setpoint 1

40.0

%

C00039/2

Fixed setpoint 2

Fixed setpoint 2

60.0

%

C00039/3

Fixed setpoint 3

Fixed setpoint 3

80.0

%

C00087

Rated motor speed

This value can be obtained from the motor nameplate.
After the motor to be used has been selected from the
motor catalogue,
the suitable value can be entered automatically.

1320

rpm

C00089

Rated motor
frequency

This value can be obtained from the motor nameplate.
After the motor to be used has been selected from the
motor catalogue,
the suitable value can be entered automatically.

50

Hz

C00105

Deceleration time −
quick stop

The set deceleration time determines the ramp slope
at quick stop

5.0

s

C00120

Motor overload
threshold (I

2

xt)

Operating threshold for the error message "OC6:
Motor overload (I

2

xt)"

100

%

C00129

Value brake resistor

Resistance value of the connected brake resistor

220

W

C00165

Error information

Display of the error numbers divided into sectors in
the case of an error

C00173

Mains voltage

Selection of the mains voltage for operating the
device.

0: 400 V

C02580

Holding brake:
Operating mode

Selection of the operating mode for holding brake
control

0: Off