Commissioning

Overview of the commissioning steps with keypad
Keypad control

6

l

88

EDS84DG752 EN 4.0

3. Check switch at the bottom of the drive unit:

DIP1/1 must be "OFF" (Lenze setting) in order that the parameters can be overwritten
via »Engineer«, keypad, or fieldbus.

4. If required, carry out communication settings via the DIP switch on the

Communication Unit for fieldbus communication.

The communication settings depend on the fieldbus used.

5. Fasten the controller by means of the 4 screws.

6. Switch on voltage supply of the controller.

7. Connect keypad.

– Remove the cover of the diagnostic interface on the top of the device and connect

the keypad to the diagnostic interface.

– After attaching the keypad or switching on the controller with keypad attached,

the connection between keypad and controller is established. The process is
completed when the code C00051 appears in the display.

Keypad display

Action

MCTRL: Act speed val.

C00051

0 rpm

Use left function key

• to change to main menu.

8. Load Lenze setting to controller.

– For this purpose, the device command "Load Lenze setting" is available which can

be executed via code C00002/1 with the keypad:

)

Note!

If the Lenze settings are loaded, changed values are overwritten. Default
settings for a specific motor, e.g. for a Drive Package, would be reset with
"Load Lenze settings".

Keypad display

Action

Par1 8400 motec
User menu
...
Logbook
Quick commissioning

A Use navigation key

ƒ to select the "Quick commissioning" menu in the main

menu.

B Use navigation key

… to change to the "Quick commissioning" menu.

Par1 Quick commissioning
Terminals
Keypad

Use navigation key

…to change to the "Terminals" menu.

Load Lenze setting
C00002/1

A Use the left function key

‰ to change to the editing mode for C00002/1.

B Use navigation key

ƒ to select the "1: On/Start" entry in the selection list.

C Use the right function key

‹ to accept the executed change and quit the

editing mode.
– The load process may take a couple of seconds.