1 digital inputs, Digital inputs, Technical data – Lenze 8400 motec Manual User Manual

Page 48: Control terminals digital inputs, Profibus, As−i

Advertising
background image

Technical data

Control terminals
Digital inputs

4

l

48

EDS84DG752 EN 4.0

4.7.1

Digital inputs

X4

Pin / name

Features

Rated value

RFR
DI1
DI2
DI3
DI4
DI5

Controller enable
Digital inputs

according to IEC 61131−2, type 1
or
DI1/DI2: Two−track frequency input for HTL
encoder 0 ... 10 kHz (parameterisable)

DI3 ... DI5 not available for NO BUS

X3

Pin / name

Features

Rated value

24O
GND

24−V supply of external sensors or
potential−free contacts

according to IEC 61131−2

max. total current

100 mA

In the E84DGFCx9xx version, max. four digital inputs are assigned to the M12 plugs. The
plugs are mounted to the connection positions Ax, depending on the fieldbus.

CANopen

A1

DI − E84DGFCC9xx

A4

DI − E84DGFCC9xx

1

2

3

4

5

1

24O

1

2

3

4

5

1

24O

2

DI2

2

DI4

3

GND

3

GND

M12 female
socket A−Coding

4

DI1

M12 female
socket A−Coding

4

DI3

5

n. c.

5

n. c.

PROFIBUS

A4

DI − E84DGFCP9xx

1

2

3

4

5

1

24O

2

DI2

3

GND

M12 female
socket A−Coding

4

DI1

5

n. c.

AS−i

A3

DI − E84DGFCA9xx

A4

DI − E84DGFCA9xx

1

2

3

4

5

1

24O

1

2

3

4

5

1

24O

2

DI2

2

DI4

3

GND

3

GND

M12 female
socket A−Coding

4

DI1

M12 female
socket A−Coding

4

DI3

5

n. c.

5

n. c.

Advertising